Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add filters








Year range
1.
Chinese Medical Journal ; (24): 465-469, 2012.
Article in English | WPRIM | ID: wpr-262589

ABSTRACT

<p><b>BACKGROUND</b>There is no research, either at home or abroad, focusing on assessing the cardiopulmonary functional reserve and exercise tolerance in patients with pulmonary embolism (PE), but the benefits of early exercise are well recognized. The goals of this study were to assess cardiopulmonary functional reserve in treated PE patients using the inert gas rebreathing method of the cardiopulmonary exercise test (CPET), and to compare it with traditional methods.</p><p><b>METHODS</b>CPET on the bicycle ergometer were performed in 40 patients with age, gender, body mass index, systolic blood pressure, and pulmonary function matched. The first group was the PE group composed of 16 PE patients (5 male, 11 female) who were given the standard antithrombotic therapy for two weeks. The second group was composed of 24 normal individuals (10 male, 14 female). Both groups were evaluated by cardiac ultrasound examination, 6-minute walking test (6MWT), and CPET.</p><p><b>RESULTS</b>(1) Right ventricular systolic pressure (RVSP) in the PE group increased significantly compared to the control group, (34.81 ± 8.15) mmHg to (19.75 ± 3.47) mmHg (P < 0.01). But neither right atrial end-systolic diameter (RASD) nor right ventricular end-diastolic diameter (RVDD) in the PE patients had changed when compared with the controls. The 6-minute walk distance was significantly reduced in the PE patients compared with normal subjects, (447.81 ± 79.20) m vs. (513.75 ± 31.45) m (P < 0.01). Both anaerobic threshold oxygen consumption (VO(2)AT) and peak oxygen consumption (VO(2)peak) were significantly lower in patients with PE, while CO(2) equivalent ventilation (VE/VCO(2) slope) was higher; VO(2)AT (9.44 ± 3.82) ml×kg(-1)×min(-1) vs. (14.62 ± 2.93) ml×kg(-1)×min(-1) (P < 0.01) and VO2peak (12.26 ± 4.06) ml×kg(-1)×min(-1) vs. (23.46 ± 6.15) ml×kg(-1)×min(-1) (P < 0.01) and VE/VCO(2) slope 35.47 ± 6.66 vs. 26.94 ± 3.16 (P < 0.01). There was no significant difference in resting cardiac output (CO) between the PE and normal groups, whereas peak cardiac output (peak CO) and the difference between exercise and resting cardiac output (ΔCO) were both significantly reduced in the PE group; peak CO (5.97 ± 2.25) L/min to (8.50 ± 3.13) L/min (P < 0.01), ΔCO (1.29 ± 1.59) L/min to (3.97 ± 2.02) L/min (P < 0.01). (2) The 6-minute walk distance did not correlated with CPET except for the VO2 peak in patients with PE, r = 0.675 (P < 0.01).</p><p><b>CONCLUSIONS</b>The cardiopulmonary functional reserve was reduced in patients with PE. CPET is an accurate, quantitative evaluation of cardiopulmonary functional reserve for PE patients.</p>


Subject(s)
Aged , Female , Humans , Male , Middle Aged , Exercise Test , Methods , Exercise Tolerance , Physiology , Oxygen Consumption , Physiology , Pulmonary Embolism , Therapeutics
2.
Chinese Journal of General Practitioners ; (6)2005.
Article in Chinese | WPRIM | ID: wpr-683465

ABSTRACT

Objective To observe the efficacy and safety of applying sirolimus-eluting stents in emergency percutaneous coronary intervention (PCI) for the patients with acute myocardial infarction (AMI).Methods In total,220 patients with AMI were enrolled in this study at Shanghai Tongji Hospital, divided into two groups,one with bare-metal stent and the other with sirolimus-eluting stent.Cardiovascular fatality,major adverse cardiac events (MACE) and target vessel revascularization (TVR) were observed one and six months after PCI in the two groups.Results There was no significant difference in overall fatality and MACE in the 1~(st) or 6~(th) months after PCI between the two groups.Three cardiogenic deaths occurred in bare-metal stent group with a fatality of 2.8 percent,and five deaths in sirolimus-eluting stent group with a fatality of 4.5 percent in six months after PCI.However,rate of restenosis in those with sirolimus-eluting stents was significantly lower than that of bare-metal stents (6.0 percent vs 16.1 percent,P

SELECTION OF CITATIONS
SEARCH DETAIL